Message 11/486 Alex Kraus Oct 16, 2000 01:02:50 pm +0200 X-Authentication-Warning: vlbi_pc.mpifr-bonn.mpg.de: akraus owned process doing -bs Date: Mon, 16 Oct 2000 13:02:50 +0200 (MEST) To: evntech@jb.man.ac.uk Subject: EVNtech: EB TOG report Sender: owner-evntech@jb.man.ac.uk Precedence: bulk EVN Station: Effelsberg Author : Alex Kraus Date : Oct 12, 2000 Personnel Changes ----------------- none Brief Report of Last EVN Session -------------------------------- Problems occured with the 5cm receiver. Either the system temperature and the calibration signal showed a large variation with frequency. Especially at 6.65GHz, the system temperature was very high (500K). A major revision of the receiver will take place in the near future. The other parts went smoothly. Problems Encountered Since Last TOG Meeting ------------------------------------------- Sometime the VLBA-FS-computer (a VX Works system) crashes without obvious reason. An upgrade should take place soon. Changes/Upgrades Made to Hardware/Software ------------------------------------------ o Current FS version: 9.4.13. o Telescope: The wear of the azimuth-gears still require a limitation of the azimuth slewing rate to 20deg/min. New gears are ordered and will delivered until fall 2001.